Ecophon Focus™ frieze Ds/Dg

For applications where a smooth continuous transition between the ceiling and the wall is needed. The frieze can be connected to the wall without any visible trims. The tiles are not demountable.
SYSTEM RANGE
Size, mm
2400
X
600
T24
Thickness 20
Inst. diagr. m239

The system consists of Ecophon Focus frieze tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the tile is covered with glass tissue. The edges are painted. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,f,w=24 dB according to ISO 10848-2 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=190 according to ASTM E 1111 and E 1110.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Focus frieze 200 mm o.d.s.
o.d.s = overall depth of system

Focus frieze system
Focus frieze with Connect Frieze trim 0562
Focus frieze with Connect Frieze bracket 0043
ACCESSABILITY: The tiles are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications. The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The system is classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: The individual panel can take additional load according to the conditions in Functional demands, Mechanical properties.
INSTALLATION: Installed according to installation diagram M239, which includes information regarding minimum overall depth of system.
www.ecophon.com Cadsupport, product selector, specification, maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M239) for Ecophon Focus frieze Ds/Dg
Size, mm
2400x600
Focus Frieze Ds/Dg as required
1 Focus Ds or Dg as required
2 Connect T24 Main runner as required
3 Connect T24 Cross tee as required
4 Connect Adjustable hanger as required
5 Connect Hanger clip as required
6 Connect Frieze bracket 0043, installed at 500 mm centre. Minimum free depth above tile 150 mm. as required
7 Connect Frieze trim 0562, fixed at 300 mm centres. as required
8 Connect Perimeter tile clip 1080 as required
9 Connect Angle trim as required
10 Acrylic sealent as required
11 Connect Wall bracket 0525 as required
12 Focus frieze (can be divided in two parts if width is less than 300 mm) as required