Ecophon Master™ C

Suitable for schools, open plan offices or other premises where strict demands are made on good acoustics and speech intelligibility. Ecophon Master C is installed in a suspended grid system or directly to the soffit, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
SYSTEM RANGE
Size, mm
600
X
600
Concealed grid
Glue
Thickness 40
Inst. diagr. m113
m111
m57

The systems consist of Ecophon Master C tiles and Ecophon Connect grid systems, with an approximate weight of 5,5 kg/m². The tiles are manufactured from high density glass wool. The visible surface is available with three different surface coatings to meet different sound absorption needs: alpha (Akutex T coating), beta and gamma. The back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,c,w=31 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=33 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=190 (Master C/alpha) according to ASTM E 1111 and E 1110. Master C/beta and Master C/gamma are not suitable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Master C/alpha 200 mm o.d.s.
···· Ecophon Master C/beta 200 mm o.d.s.
--- Ecophon Master C/gamma 200 mm o.d.s.
o.d.s = overall depth of system




— Ecophon Master C/alpha 40 mm o.d.s.
···· Ecophon Master C/beta 40 mm o.d.s.
--- Ecophon Master C/gamma 40 mm o.d.s.
o.d.s = overall depth of system

Product Master C/alpha Master C/beta Master C/gamma
O.d.s. mm 400 200 40 400 200 40 400 200 40
Absorption class   A A   C C   E E
NRC 0.85   0.95            
SAA 0.86   0.95            

Master C tile
Section of Master C system
Master C system
Master C with Connect Channel trim
ACCESSIBILITY: The tiles are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m111, 600x600 40 160
m112, 600x600 -
m113, 600x600 -
m57, 600x600 40 160
m96, 1200x600 -
m96, 600x600 -
INSTALLATION: Installed according to installation diagram M57, M111 or M113 (see Master B), which include information regarding minimum overall depth of system. Installation with glue according to M113 requires smooth, clean and dry sub-surfaces of concrete, lightweight concrete, plaster or wood fibre. It is advisable to carry out adhesion tests on painted or suspect surfaces.
www.ecophon.co.uk, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M111) for Master C, direct installation
Size, mm
600x600
Master C 2.8/m²
1 Connect Z-profile 0227, installed at 600 mm centres 1.7 m/m²
2 Connect Direct fixing plate 0214, installed at 1200 mm centres 1.4/m²
3 Connect Splice Connector Z 0501 0.4/m²
4 Connect Spline 0219, L=150 mm 2.8/m²
5 Connect T-spline 0011, L=600 mm. To comply with fire class "Tändskyddande beklädnad" 2.8/m²
6 Connect Angle trim, fixed at 300 mm centres as required
7 Connect Shadow-line trim, fixed at 300 mm centres as required
8 For installation of floating ceilings: Connect Channel trim 0623 as required
Quantity specification (excl. wastage)
Installation diagram (M112) for Master C, direct installation with Fixing plate
Size, mm
600x600
Master C 2.8/m²
1 Connect Direct fixing plate 0299 2.8/m²
2 Connect Spline 0219, L=150 2.8/m²
3 Connect Angle trim, fixed at 300 mm centres as required
Quantity specification (excl. wastage)
Installation diagram (M113) Master B or C, using A-cement
Size, mm
600x600
Master C 2.8/m²
1 Master B or C. Master C: Visible edges should be painted 2.8/m²
2 Connect A-cement 0044, diameter 40 mm 1.4 l/m²
3 Master C: Connect Splines 0219, L=150 mm 2.8/m²
4 For installation of floating ceilings: Connect Wood trim 2141, L=2500 as required
Quantity specification (excl. wastage)
Installation diagram (M57) for Master C, suspended installation
Size, mm
600x600
Master C 2.8/m²
1 Connect T24 Main runner 8101, installed at 1200 mm centres 0.9 m/m²
2 Connect Wire clip 0024 1.4/m²
3 Connect Z-profile, installed at 600 mm centres 1.7 m/m²
4 Connect Splice Connector Z 0501 0.4/m²
5 Connect Spline 0219, L=150 mm 2.8/m²
6 Connect T-spline 0011, L=600 mm 2.8/m²
7 Connect Adjustable hanger, installed at 1200 mm centres (max distance from wall 600 mm) 0.7/m²
8 Connect Angle trim, fixed at 300 mm centres as required
9 Connect Shadow-line trim, fixed at 300 mm centres as required
10 Connect Inspection 0480 as required